§ 3285.303. Piers.
1,029 words·~5 min read·
/us/cfr/t24/s§ 3285.303·A research copy — for the controlling text, always check the official state or federal source. Not legal advice.
(a)General. The piers used must be capable of transmitting the vertical live and dead loads to the footings or foundation.
(b)Acceptable piers---materials specification.
(1)Piers are permitted to be concrete blocks; pressure-treated wood with a water borne preservative, in accordance with AWPA Standard U1-04 (incorporated by reference, see § 3285.4) for Use Category 4B ground contact applications; or adjustable metal or concrete piers.
(2)Manufactured piers must be listed or labeled for the required vertical load capacity, and, where required by design, for the appropriate horizontal load capacity.
(c)Design requirements.
(1)Load-bearing capacity. The load bearing capacity for each pier must be designed to include consideration for the dimensions of the home, the design dead and live loads, the spacing of the piers, and the way the piers are used to support the home.
(2)Center beam/mating wall support must be required for multi-section homes and designs must be consistent with Tables 2 and 3 to § 3285.303 and Figures A, B, and C to § 3285.310.
(d)Pier loads.
(1)Design support configurations for the pier loads, pier spacing, and roof live loads must be in accordance with Tables 1, 2, and 3 to § 3285.303 and the MHCSS. Other pier designs are permitted in accordance with the provisions of this subpart.
(2)Manufactured piers must be rated at least to the loads required to safely support the dead and live loads, as required by § 3285.301, and the installation instructions for those piers must be consistent with Tables 1, 2, and 3 to this section. ::: {width="100%"} ::: {.table_head} Table 1 to § 3285.303---Frame Blocking Only/Perimeter Support Not Required Except at Openings ::: ::: {.gpotbl_div} Pier spacing Roof live load
(psf)Location Load (lbs.) 20 Frame 2,900 4 ft. 0 in. 30 Frame 3,300 40 Frame 3,600 20 Frame 4,200 6 ft. 0 in. 30 Frame 4,700 40 Frame 5,200 20 Frame 5,500 8 ft. 0 in. 30 Frame 6,200 40 Frame 6,900 20 Frame 6,800 10 ft. 0 in. 30 Frame 7,600 40 Frame 8,500 ::: ::: Notes: 1. See Table to § 3285.312 for cast-in-place footing design by using the noted loads. 2. Table 1 is based on the following design assumptions: maximum 16 ft. nominal section width (15 ft. actual width), 12" eave, 10" I-beam size, 300 lbs. pier dead load, 10 psf roof dead load, 6 psf floor dead load, 35 plf wall dead load, and 10 plf chassis dead load. 3. Interpolation for other pier spacing is permitted. 4. The pier spacing and loads shown in the above table do not consider flood or seismic loads and are not intended for use in flood or seismic hazard areas. In those areas, the foundation support system is to be designed by a professional engineer or architect. 5. See Table to § 3285.312 for sizing of footings. ``` ``` ``` ``` ``` Table 2 to § 3285.303---Frame Plus Perimeter Blocking/Perimeter Blocking Required ::: {.gpotbl_div} Maximum pier spacing Roof live load(psf) Location Load (lbs.) Frame 1,400 4 ft. 0 in. 20 Perimeter 1,900 Mating 3,200 Frame 1,400 4 ft. 0 in. 30 Perimeter 2,300 Mating 3,800 Frame 1,400 4 ft. 0 in. 40 Perimeter 2,600 Mating 4,400 Frame 1,900 6 ft. 0 in. 20 Perimeter 2,700 Mating 4,700 Frame 1,900 6 ft. 0 in. 30 Perimeter 3,200 Mating 5,600 Frame 1,900 6 ft. 0 in. 40 Perimeter 3,700 Mating 6,500 Frame 2,400 8 ft. 0 in. 20 Perimeter 3,500 Mating 6,100 Frame 2,400 8 ft. 0 in. 30 Perimeter 4,200 Mating 7,300 Frame 2,400 8 ft. 0 in. 40 Perimeter 4,800 Mating 8,500 Frame 2,900 10 ft. 0 in. 20 Perimeter 4,300 Mating 7,600 Frame 2,900 10 ft. 0 in. 30 Perimeter 5,100 Mating 9,100 Frame 2,900 10 ft. 0 in. 40 Perimeter 6,000 Mating 10,600 ::: Notes: 1. See Table to § 3285.312 for cast-in-place footing design by using the noted loads. 2. Mating wall perimeter piers and footings only required under full height mating walls supporting roof loads. Refer to Figures A and B to § 3285.310. 3. Table 2 is based on the following design assumptions: maximum 16 ft. nominal section width (15 ft. actual width), 12" eave, 10" I-beam size, 300 lbs. pier dead load, 10 psf roof dead load, 6 psf floor dead load, 35 plf wall dead load, and 10 plf chassis dead load. 4. Interpolation for other pier spacing is permitted. 5. The pier spacing and loads shown in the above table do not consider flood or seismic loads and are not intended for use in flood or seismic hazard areas. In those areas, the foundation support system is to be designed by a professional engineer or architect. 6. See Table to § 3285.312 for sizing of footings. ``` ``` ``` ``` ``` Table 3 to § 3285.303---Ridge Beam Span Footing Capacity ::: {.gpotbl_div} Mating wall opening
(ft)Roof live load
(psf)Pier and footing load (lbs.) 20 1,200 5 30 1,600 40 1,900 20 2,300 10 30 3,100 40 3,800 20 3,500 15 30 4,700 40 5,800 20 4,700 20 30 6,200 40 7,500 20 5,800 25 30 7,800 40 9,700 20 7,000 30 30 9,300 40 11,600 20 8,100 35 30 10,900 40 13,600 ::: Notes: 1. See Table to § 3285.312 for cast-in-place footing design by using the noted loads. 2. Table 3 is based on the following design assumptions: maximum 16 ft. nominal section width (15 ft. actual width), 10″ I-beam size, 300 lbs. pier dead load, 10 psf roof dead load, 6 psf floor dead load, 35 plf wall dead load, and 10 plf chassis dead load. 3. Loads listed are maximum column loads for each section of the manufactured home. 4. Interpolation for maximum allowable pier and column loads is permitted for mate-line openings between those shown in the table. 5. The pier spacing and loads shown in the above table do not consider flood or seismic loads and are not intended for use in flood or seismic hazard areas. In those areas, the foundation support system must be designed by a professional engineer or registered architect. 6. See Table to § 3285.312 for sizing of footings. ``` ```